28 Programmer’s Guide
Hardware Configuration
Before using an ACR controller, you must define for the firmware
what specific hardware is installed. The default configuration is as
follows:
CONFIG ENC8 DAC4 DAC4 ADC8
The command uses four arguments— encoders, module 0, module 1,
and module 2.
Encoder: The encoder argument is the number of encoder channels
installed.
NONE, ENC2, ENC4, ENC6, ENC8, ENC10
Module 0: The module 0 argument is the type of module installed in
the first SIMM socket.
NONE, DAC2, DAC4, STEPPER2, STEPPER4, DACSTEP2, DACSTEP4
Module 1: The module 1 argument is the type of module installed in
the second SIMM socket.
NONE, DAC2, DAC4, STEPPER2, STEPPER4
Module 2: The module 2 argument is indicates whether an ADC
module is installed in the third SIMM socket.
NONE, ADC8
In ACR-View, the New Controller Wizard determines the CONFIG
statement for you.
Defining Hardware Configuration
To define the hardware, use the CONFIG command.
Reviewing Your Configuration
To view the current configuration, enter CONFIG with no
arguments.